Comparison of the patient and partner satisfaction with 700CX and Titan penile prostheses


1 12 de Octubre University Hospital, Department of Urology, Madrid, Spain
2 Fundació Puigvert, Department of Andrology, Barcelona, Spain

Correspondence Address:
Javier Romero Otero
12 de Octubre University Hospital, Department of Urology, Madrid, Spain

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1008-682X.172822

Rights and Permissions

Most widespread three-component penile prosthesis models are 700CX and Titan ® . Our purpose is to assess patient and partner satisfaction after the first implant. This is a multicenter, retrospective, nonrandomized study in which all patients who met the inclusion criteria between 2009 and 2013 were included. In total, 248 patients agreed to participate. To evaluate patient satisfaction, a validated but modified 11-question questionnaire was completed (EDITS); and a nonvalidated two-item questionnaire was given to the partner. Statistical analysis used an ordinal logistic regression model. Two hundred and forty-eight patients (194 with 700CX vs 54 with Titan®) and 207 couples completed the questionnaire (165 with 700CX vs 42 with Titan®). Overall satisfaction was high. Both showed great reliability for sexual intercourse and high compliance with prior expectations. Most patients were able to manage the penile prosthesis correctly within 6 months. Postoperative penile shortening led to some dissatisfaction in 42% and 46% of cases (700CX /Titan®). Significant differences were found in three questions of patients' questionnaire. There were more patients satisfied with the 700CX (P = 0.0001). No patient with Titan® implant took longer than 6 months to optimal management. Only 4% of patients with 700CX implant were dissatisfied with the deflation, in contrast to 24% with the Titan® (P = 0.0031). Of the two partners' questions, one showed a statistically significant difference (P = 0.0026). It seems that group 700CX would recommend to re-implant the prosthesis with a greater tendency. The overall satisfaction was very high for both prostheses. The final aspect of the erected and flaccid penis was satisfactory, but both groups showed significant discontent with its final size. Partners' overall satisfaction was high.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3030    
    Printed107    
    Emailed0    
    PDF Downloaded249    
    Comments [Add]    
    Cited by others 5    

Recommend this journal