ORIGINAL ARTICLE
Year : 2017  |  Volume : 19  |  Issue : 3  |  Page : 286-290

Prospective validation of %p2PSA and the Prostate Health Index, in prostate cancer detection in initial prostate biopsies of Asian men, with total PSA 4-10 ng ml-1


1 Department of Urology, National University Hospital, National University Health System, Singapore
2 Department of Urology, Tan Tock Seng Hospital, Singapore
3 Saw Swee Hock School of Public Health, National University of Singapore, Singapore
4 Department of Laboratory Medicine, National University Hospital, Singapore
5 Department of Urology, Alexandra Hospital, Jurong Health, Singapore
6 Department of Laboratory Medicine, Tan Tock Seng Hospital, Singapore
7 Department of Pathology, National University Hospital, Singapore

Correspondence Address:
Dr. Lincoln GL Tan
Department of Urology, National University Hospital, National University Health System, Singapore

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1008-682X.168687

Rights and Permissions

Despite its widespread use for prostate cancer screening, low specificity makes PSA a suboptimal biomarker, especially in the diagnostic "gray zone" of 4-10 ng ml-1 . False-positives lead to unnecessary biopsies with attendant morbidities. This is the first prospective validation study of %p2PSA and the Prostate Health Index (PHI) in Asian men presenting with a total PSA between 4.0 and 10 ng ml-1 . We studied 157 Asian men between 50 and 75 years old, with normal per rectal prostate examinations, undergoing their first prostate biopsy, using a standardized biopsy protocol, for PSA levels of 4-10 ng ml-1 . Thirty (19.1%) were found to have prostate cancer on biopsy. Statistically significant differences between patients with and without prostate cancer were found for total PSA, p2PSA, %p2PSA, and PHI. The areas under the curve of the receiver operating characteristic curve for total PSA, %fPSA, %p2PSA, and PHI were 0.479, 0.420, 0.695, and 0.794, respectively. PHI predicts prostatic biopsies results best. At a sensitivity of 90%, the specificity (95% CI) of PHI was 58.3%, more than triple the specificity of total PSA at 17.3%, potentially avoiding 77 (49%) unnecessary biopsies. Similar to studies in mainly Caucasian populations, we have prospectively shown that %p2PSA and PHI greatly outperform total and free to total PSA ratio, in the detection of prostate cancer at first biopsy. Higher PHI levels also correspond to increasing the risk of detecting GS ≥7 cancers. We have validated the use of PHI to aid decision-making regarding prostate biopsies in Asian men with serum PSA between 4 and 10 ng ml-1 .


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2972    
    Printed173    
    Emailed0    
    PDF Downloaded375    
    Comments [Add]    
    Cited by others 10    

Recommend this journal